Private connection with measurement vertically from building side generate.

It is put – outgoing by a building side – a private connection at right angles in a management. On the building side a distance to be given is used and the base line is oriented on account of the positioning in the graphics. With the orientation the building corner is pulled up as a zero of the measurement line lies most near with the position elective in the graphics. On the building side the given distance measure is used and included vertically in the desired management.

 

Condition

A plan must be opened.

Parametre

LTGKEY/nnnn

Object key of the private connection management to be generated.

ANSCHLUSSKEY / nnnn

Object key of the private connection.

ABZWEIGKEY / nnnn

Object key of the Hausabzweiges.

SCHIEBERKEY / nnnn

Object key of the private connection racketeer.

ANSCHLUSSSYM / nnnn

Symbolic number of the private connection symbol. The symbol is generated in the additional object (ANSCHLUSSKEY).

ABZWEIGSYM / nnnn

Symbolic number of the Hausabzweigsymbols. The symbol is generated in the additional object (ABZWEIGKEY).

SCHIEBERSYM / nnnn

Symbolic number of the Hausanschlussschiebersymbols. The symbol is generated in the additional object (SCHIEBERKEY).

DISTANCE/nn

Distance füe the connection symbol of the next point in metres (on the building side).

ABSTAND2/nn

Distance Hausanschlussschiebersymbols of the next point in metres.

VERMASSUNGKEY / nnnn

Object key for dimensioning object.

VERMASSUNGSSYM / nnnn

Symbolic number dimensioning object.

ENDMASSSYM / nnnn

Symbolic number final measure.

VERLSYM / nnnn

Symbolic number lengthening.

VERMASSUNGTDKY / nnnn

Text number dimensioning object.

VERMASSUNDKY / nnnn

Text number dimensioning object.

GRADUATION/nnnn

Plan graduation.

NACHKOMMA/nn

Number of the postcomma places with the dimensioning object.

/h

Announcement of this auxiliary text.

 

Return value

Value

Description

0

Call was carried out successfully

But

Mistake appeared

Dialogue

If parametres are not given for the object education, these are not looked by the functional call. Therefore can be steered via selection of the functional attributes which components of a private connection are generated.

Then are to be answered a row by queries to the Abszisse.

As the first the query of a point occurs near the building side intended for the private connection. Here with the distance of the graphics release is determined relatively to the building side, and the most near lying building corner as a starting point to clear away of the distance measure are pulled up.

Then a graphics release is expected to the identification of the management relevant for the private connection.

 

Example

HAsenkrecht LTGKEY / 19494 ANSCHLUSSKEY / 19740 ANSCHLUSSSYM / 19241 ABZWEIGKEY / 19747 ABZWEIGSYM / 19247 STOOD OFF / 1.5

A private connection with 1.5 m is integrated by the elective house corner in a provider's management and the private connection management, the private connection and the Abzweigobjekt are generated.